DWYER SERIES 2000 MAGNEHELIC DIFFERENTIAL PRESSURE GAGE

  • Brand:
    DWYER

Description

SPECIFICATIONS

  • Service: Air and non-combustible, compatible gases (natural gas option available).
  • Note: May be used with hydrogen. Order a Buna-N diaphragm. Pressures must beless than 35 psi.
  • Wetted Materials: Consult factory.
  • Housing: Die cast aluminum case and bezel, with acrylic cover. Exterior finish iscoated gray to withstand 168 hour salt spray corrosion test.
  • Accuracy: ±2% of FS (±3% on - 0, -100 Pa, -125 Pa, 10MM and ±4% on - 00, -60Pa, -6MM ranges), throughout range at 70°F (21.1°C).
  • Pressure Limits: -20 in Hg to 15 psig† (-0.677 to 1.034 bar); MP option: 35 psig(2.41 bar); HP option: 80 psig (5.52 bar).
  • Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standardgages only. See Overpressure Protection Note on next page
  • Temperature Limits: 20 to 140°F* (-6.67 to 60°C). -20°F (-28°C) with lowtemperature option.Size: 4˝ (101.6 mm) diameter dial face.
  • Mounting Orientation: Diaphragm in vertical position. Consult factory for otherposition orientations.
  • Process Connections: 1/8˝ female NPT duplicate high and low pressure taps -one pair side and one pair back.
  • Weight: 1 lb 2 oz (510 g), MP & HP 2 lb 2 oz (963 g).
  • Standard Accessories: Two 1/8˝ NPT plugs for duplicate pressure taps, two 1/8˝pipe thread to rubber tubing adapter, and three flush mounting adapters withscrews. (Mounting and snap ring retainer substituted for three adapters in MP &HP gage accessories.)
  • Agency Approval: RoHS.
  • Note: -SP models not RoHS approved.